Manufactured in Subic Bay since 2012 · Nationwide installation +63 47 250 2890 +63 917 177 9434 sales@ifi.com.ph
All systemsNoiseSHIELDHeatSHIELDWallSHIELDAgriSHIELD
Home›SHIELD Range›WallSHIELD

Combined thermal and acoustic performance, inside the wall

WallSHIELD is dense-packed into wall and partition cavities before the board goes on, filling the cavity completely. The result is one integrated solution for better thermal and acoustic performance between spaces.

1.00NRC at 76 mm (3″)
R-3.6Per inch of thickness
Class AFire rated to ASTM E84
Dense-packDesigned to resist settling
100%Cavity fill around services
Non-corrosiveSuitable for steel studs
Why WallSHIELD

Put your walls to work

◫

Privacy between spaces

Meeting rooms, hotel rooms, consulting rooms and executive offices — WallSHIELD adds sound-absorbing insulation within drywall cavities, helping support better acoustic separation as part of a properly designed partition assembly.

⧉

Two problems, one trade

Thermal and acoustic performance delivered through a single insulation installation, sequenced once in the programme.

◍

Conforms to the cavity

Dense-pack flows around studs, noggings, conduit, boxes and pipework — helping minimise gaps around framing and services behind the board.

⇩

Designed to resist settling

Installed at density rather than laid in — dense-pack installation helps maintain consistent cavity coverage over time.

⚙

Designed for framed walls

Non-corrosive to steel studs and fixings, and borate-treated against mold and pests in a permanently enclosed cavity.

⏱

Fast on programme

Installed into open framing before boarding, in a single visit — so WallSHIELD is coordinated with the drywall contractor's installation sequence.

Applications

Where WallSHIELD performs

Drywall partitionsHotel guest roomsOffices & meeting roomsRecording studiosResidential interiorsConsulting roomsParty wallsResort bungalows
Tested Performance

Acoustic & thermal data

IFI cellulose, tested to ASTM C423 on solid backing. Performance varies with installed thickness and the complete wall assembly; final specification is determined according to project requirements.

ThicknessImperialR-ValueNRC
16 mm5⁄8″2.20.55
25 mm1″3.60.75
38 mm1½″5.50.90
50 mm2″7.20.95
64 mm2½″9.21.00
76 mm3″10.81.00

Material performance at the stated thickness. Assembly performance (STC/Rw) depends on the full partition build-up — board type, layers, stud type and junction detailing. IFI can advise on WallSHIELD specification within the proposed partition build-up.

Request the technical data pack

In the Field

WallSHIELD installed

WallSHIELD dense-packed into steel-stud framingCavity filled completely around the frame, ready for boardingFull-height wall fill along a tunnel-ventilated house

Quieter rooms start inside the wall.

Share your plans, photos or project details and we'll help define the right WallSHIELD specification for your space — from thickness and coverage to finish and next steps.

Request a Quote